Projects
Pressure Rerating Assessment
Industry
Oil & Gas
Services
PV Elite, Re-rating
Location
UK - England
In order to utilise existing equipment for new purposes, an oil & gas client required an assessment of their existing equipment to ensure that the equipment would remain safe under the new, increased, operating conditions. This equipment included pressure vessels such as columns, drums, and heat exchangers.
The challenge
The set of equipment in question had been in operation for multiple decades. To qualify the re-rating of this equipment without replicating the original design calculations would require careful consideration.
The DOCAN solution
Using a combination of manual calculations and the PV Elite pressure vessel modelling software, we conducted a full assessment of each vessel to determine if any of the vessels would become non-code compliant due to the rerating and what remedial action may be required.
This work also included a review of the vessel foundation for suitability under hydrotesting, and a review of Pressure Equipment Directive (PED) on the client’s behalf.
The outcome
The client now has a codified assessment which can be used to substantiate the rerating of the vessels and has confidence that the vessels will remain safe for the rest of their service life.
Project summary
Task | Application | DOCAN Expertise | Pressure Vessels | Rerating | Heat Exchangers | PV ELITE | Wind Loading | Seismic Loading |
---|---|---|---|---|---|---|---|---|
Proficiency in use of engineering standards | BS5500 | |||||||
PD5500 | ||||||||
TEMA | ||||||||
BS6399 | ||||||||
EN 1998:1/Eurocode 8 | ||||||||
Analysis | Information gathering | |||||||
Modelling | ||||||||
Assessment | ||||||||
Reporting |